Fire-Rated Doors in Etobicoke
Labelled steel and wood fire doors for Etobicoke — supplied as complete assemblies with their frames and hardware, installed, inspected against NFPA 80 and repaired within the listing. From our shop at 14-1645 Bonhill Road, Mississauga.
Hollow metal doors and frames we've installed and serviced in Etobicoke — for The Westin Airport, Seven Building Services Inc, RAP Holdings Inc, Takol 67-69 Westmore Inc, Circle Ridge Construction Inc, Edge Group Ltd — among many more businesses here. Dependable people, quality products, since 1979.
Recent fire-rated door projects in Etobicoke and surrounding areas

Hollow metal doors & frames
Mariani Metal Fabricators

Hollow metal doors & frames
Seven Building Services Inc

Wood doors
Primary Construction Inc
Fire-Rated Doors across Etobicoke
We work throughout Etobicoke — Rexdale, The Queensway, Islington-City Centre, Woodbine and the blocks around them. The buildings here are mostly logistics, light manufacturing and food processing, and each puts different demands on a door: traffic volume, insurance and fire requirements, and how much downtime an opening can afford. Etobicoke’s 365,143 residents keep those buildings busy.
- Population
- 365,143
- Main industries
- logistics, light manufacturing, food processing and retail
- Building stock
- high-bay logistics and distribution warehouses, food processing and cold-storage facilities, flex-industrial and multi-tenant industrial condos and big-box retail and power centres
- Business parks
- Rexdale, The Queensway, Islington-City Centre and Woodbine
- Serving since
- 1979
- Rexdale
- The Queensway
- Islington-City Centre
- Woodbine
- Six Points
Broken fire-rated doors in Etobicoke: we dispatch 24/7.
Etobicoke is roughly a 15-minute run from our Mississauga shop — less if a technician is already in the area — so a truck is usually on site the same day.
Emergency board-up, security and make-safe first — permanent repair scheduled after.
The two fire-rated doors a building in Etobicoke uses — steel and wood
A fire door is not a door with a rating written on it. It is a tested assembly — leaf, frame, hinges, closer, latch and any glazing — certified together by a body such as ULC or UL, and it performs as certified only while every part of it stays as it was listed. Which of the two materials goes into a given Etobicoke opening is settled by where the door sits in the building rather than by budget: steel where the door is a tool, mineral-core wood where the door is part of the interior.
Where a building in Etobicoke carries fire-rated openings
The rating belongs to the wall first. The Ontario Building Code assigns a fire-resistance rating to a fire separation, and the closure in it — the door — gets a matching rating. In Etobicoke that lands on the same handful of openings in almost every building, and the count is usually higher than the owner expects.
Related fire door work in Etobicoke
Fire-rated openings for the work Etobicoke buildings do
The sectors that dominate Etobicoke — logistics, light manufacturing, food processing — each put fire-rated doors in different places.
Logistics
The separation here is between the racked floor and the office block: cross-corridor and office-entry doors in a fire-rated wall, and a shipping opening usually too wide for a leaf, which closes on a rolling fire shutter instead. What fails is a frame knocked out of line by a pallet truck until the latch stops throwing.
Light manufacturing
The walls that carry a rating are the ones around the process area and the electrical room, and the doors in them are steel because the leaf is in a plant. The recurring finding is a fire-rated door propped open for airflow or cable runs — the legal version of that is a magnetic hold- open tied to the alarm.
Food processing
The rating sits on the separation between production and the rest of the plant, and it has to survive washdown and a sanitation schedule. Gasketing painted over or torn out during cleaning is the commonest deficiency, and putting it back is a listing question rather than a maintenance one.
Retail
A unit in a plaza or mall carries fire-rated openings the tenant never thinks about: the back-of-house door onto the service corridor, the stock-room separation, and the mall front itself, which on a fire-rated common area closes with a shutter or curtain on alarm rather than with the shopfront glass.
Offices & business parks
Stair doors are the largest single group in the building, floor by floor, usually temperature-rise rated and on exit devices. After a fit-out the two findings are always the same: a card reader drilled into a fire-rated leaf, and clearances thrown out by a new floor finish.
Healthcare & clinics
Smoke and fire compartments cut the floor plate into sections, and those doors have to work for a bed and a crash cart as well as for the separation. Cross-corridor pairs run on hold-opens tied to the alarm, and the finished wings take wood because the door is part of the ward.
Get a fire-rated opening quoted in Etobicoke
Tell us the opening, the rating if you know it, and whether the frame is staying. If you are working from a deficiency list, send it — we quote from those every week. For urgent make-safe work, call 800-522-6825.
Common questions about fire-rated doors
Can a fire door be held open?
Only by a device that releases it. A fire-rated door has to close and latch by itself when the alarm sounds, so it cannot be wedged, tied or hooked open — but it can be held open legally on a magnetic hold-open or an electrified closer tied into the fire alarm, which releases the door on alarm. That is the correct fix for a door people keep propping, and it is usually less expensive than the deficiency it prevents.
Can wired glass still be used in fire doors?
Traditional wired glass is largely gone from new work. It passes the fire test but fails the impact requirement that now applies to hazardous locations, so new vision lites are typically fire-rated ceramic or specialty-glass products, filmed or laminated to meet impact as well. Wired glass already installed in an existing fire-rated door is generally allowed to remain until the door or the glazing is altered.
How long does a fire-rated door take?
Typically 4–6 weeks to produce a labelled door and frame once the shop drawings are approved, then 1–2 weeks to schedule the job and install it, depending on the size of the project. Certified assemblies are made to order with the hardware prep in the leaf, so the schedule is set by the fabrication rather than the installation. Inspections and most repairs, by contrast, are scheduled in days. Hanging a single labelled door and frame is usually a day on site; a building's worth of rated openings on a new build is scheduled over several weeks with the general contractor.
Fire-Rated Doors nearby
Full product details: Fire-Rated Doors